DolbyRemote Installation and Operation

Dolby Digital Parameters

 

 

 

 

does not guarantee that a valid test tone will be produced at the output of the DP567 or DP569. Dolby Digital encoding must also be active, which requires that the selected clock source be valid. The selection of a Test Tone mode automatically overrides the input format settings. All other settings remain active.

4.5.5Stream Number

Input

Input shows the input stream number for a pre-encoded signal present at the reference input.

Output

Output defines the stream number for the Dolby Digital output of the encoding process. The default is zero. If multiplex mode is currently active, the selected stream number cannot be identical to that of a stream currently being received.

4.6Reference Input

Figure 4-7Reference Input

4.6.1Reference Input

Lock Status

Lock Status shows whether the reference input has been detected and locked.

Sample Rate

Sample Rate shows the sample rate of the reference input.

Integrity

Integrity shows the data integrity of the reference input.

4-14

Page 30