DolbyRemote Installation and Operation | Dolby Digital Parameters |
|
|
|
|
does not guarantee that a valid test tone will be produced at the output of the DP567 or DP569. Dolby Digital encoding must also be active, which requires that the selected clock source be valid. The selection of a Test Tone mode automatically overrides the input format settings. All other settings remain active.
4.5.5Stream Number
Input
Input shows the input stream number for a
Output
Output defines the stream number for the Dolby Digital output of the encoding process. The default is zero. If multiplex mode is currently active, the selected stream number cannot be identical to that of a stream currently being received.
4.6Reference Input
Figure 4-7 Reference Input
4.6.1Reference Input
Lock Status
Lock Status shows whether the reference input has been detected and locked.
Sample Rate
Sample Rate shows the sample rate of the reference input.
Integrity
Integrity shows the data integrity of the reference input.