TELEPHONE INTERFACE MODULE (TIM)
4.Set the Transmission Test Set to generate 395 Hz. If
5.Adjust the generator until J11 is the same level as measured in Step 14.
6.Monitor J11, decrease the output of the Transmis- sion Test Set until the level at J11 is 10 dB below the level in Step 17.
7.Adjust R210 on the personality card for
8.Adjust R257 for a peak reading at U203, pin 7.
9.Connect an oscilloscope or DC voltmeter to EP225. Adjust R274 until EP225 is high, slowly adjust R274 until EP225 just goes low.
10.Remove the Test Set from EQU jack.
11.Set S5 for 0 and reset the card by pressing S2. A 2 should be displayed on the front
14.7.3 OUTPUT HYBRID ADJUST
1.Insert the lineman's set into the MON jack of J1 and dial the Silent telephone number. If a silent number is unavailable, call a nearby phone where the mouthpiece can be removed or covered to obtain a quiet termination.
2.Set S5 for Test 1 (section 1 open, 2, 3, 4 closed).
3.Reset the module and remove the lineman's set.
4.Connect the Transmission Test Set to J12 and adjust R44 for a level
Assume the CO maximum level is 0 dBm and that the Test Tone is sent at this level (0 dBm). Assume the level measured in Section 14.7.1, Step 6 is
to maximum level plus 8 dB for hybrid loss plus 7 dB for line loss for an Absolute Level of +3 dBm.
J12 = 0
Assume a PBX maximum level is sent at a
J12 =
5.Adjust Hybrid Balance by monitoring J11 with the Transmission Test Set.
a.Switch in/out
b.Switch
c.Tune
d.This process should be repeated several times.
The level should be
5.Set S5 for Test 3, (sections 1, 2 open, 3, 4 closed).
6.Connect the Transmission Test Set to EP221 and adjust R206 for
7.Set S5 for normal operation (all sections closed).
8.Remove the card from the extender card and insert the card back into the appropriate slot. The card displays a "2" in the
9.To display digits dialed on the system, to or from the TIM and SNM on the Alarm Display, select the following: