TELEPHONE INTERFACE MODULE (TIM)

14.11.4 XEL TERMSET RACK

Set up the equipment shown in Figures 14-24,14-25and 14-26.

1.Ensure that the jumpers have been installed on the backside of the XEL rack, where the power plug attaches (see Figure 14-24).

2.Ensure that there is a connection from Slot-12, pin 27 to the power connector ground pin (see Figure 14-24).

3.Attach the grounding strap to earth ground.

4.The XEL Rack requires -48V DC from the Switch. See Figure 14-24for wiring.

SWITCH-GND TO SLOT-12, PIN 27 CHASSIS GROUND XEL RACK

-48V

FROM SWITCH

POWER FOR

POWER FOR

SLOTS 1-6

SLOTS 7-12