| ARCHITECTURE |
| SPECIFICATIONS |
SYSTEM RACK |
|
Dimensions | 19" W x 31" D x 83.5" H |
Environment | 0° C to 50° C (32° F to 122° F) at 20% to 80% humidity (noncondensing) |
Average Power | 72 Modules x 5.1W ÷ 0.7 (efficiency) = 525W |
Average Heat | 525W x 3.6 = 1890 Btu/Hr |
Weight |
|
MODULES |
|
Dimensions | 11.5" W x 8" H (8.6" including extractors) |
Weight | 0.95 lbs. (module only) |
| 1.47 lbs. (module with Personality Card) |
Environment | 0° C to 50° C (32° F to 122° F) at 20% to 80% humidity (noncondensing) |
Maximum Power and Current | +5V DC at 0.65A = 3.25W |
| +12V DC at 0.1A = 1.2W |
| |
| |
| Total Power (less |
| Total Power (with |
| Maximum Power (with |
SYSTEM and SUBSCRIBER MANAGER | |
Computer |
|
Dimensions | 21.3" W x 18.7" D x 6.4" H |
Weight | 45 pounds |
Power and Current | 115V AC at 8A or 230V AC at 5A |
CRT |
|
Dimensions | 14.1" W x 15.3" D x 14.7" H |
Weight | 35 pounds |
Power and Current | 120V AC at 2A or 240V AC at 1.5A |
Environment | 10° C to 40° C (50° F to 104° F) at 20% to 80% humidity (noncondensing) |