TELEPHONE INTERFACE MODULE (TIM)
F2 Manual Device Control/Setup
F4 User Setup
F6 Diagnostic Control
YDisplays digits in alarm display Enter, Enter
Select F10 until the main menu is displayed All digits, both
14.8.1DID PERSONALITY CARD JUMPER SET- TINGS
TableJU | Pin | Description |
|
|
|
J205 |
| Line default disable mode - RING |
| 1 only* | Open line |
| 1 to 2 | Default to ground |
J206 |
| Line default disable mode - TIP |
| 1 only* | Open line |
| 1 to 2 | Default to ground |
J207 |
| Dial Tone or Mobile Speech Det. |
| 1 to 2 | Dial Tone Detect |
| 2 to 3 | Mobile Speech Detect |
| 1 only* | Not Used |
J208 |
| Fuse Holder |
J209 |
| Transmit Gain |
| 1 to 2 | No Gain |
| 1 only* | +6 dB Gain |
DID line connections - Tip, P1, pin 31 Ring, P1, pin 32
* Indicates normal operation.
14.8.2
The Central Office (CO) typically provides a dial up Test Tone (TT) and a Silent Line (SL). The DID alignment is more difficult since the line does not allow outward dialing, but the DID can still be aligned.
The TT from the CO is typically the maximum level the line will output or accept. The typical level is 0 dBm at the CO interface. The average level of speech on the line will typically be
The TIM should be
Input With Personality Card Installed
1.Insert 1004 Hz at
NOTE: Be sure to block the DC voltage provided by the DID by using a
2.Set S5 for Test 7 ( sections 1, 2 and 3 open, close 4).
3.Reset the module, Press S2 and release.
4.Adjust R41 for
5.Verify
6.Adjust R214 on the personality card for
7.Set S5 for normal operation (all sections closed).
8.Reset the module, Press S2 and release.
Output
1.Place a 600 ohm resistor in series with a
2.Set S5 for Test 1 (section 1 open, close 2, 3 and 4).
3.Reset the module, Press S2 and release.
4.Adjust R83 for
5.Adjust R44 to be
(This provides a maximum level of
former. Verify the level across the 600 ohm resistor and 2.2 ∝F cap is
a.DTMF Output Level:
b.Set S5 for Test 3 (sections
c.Reset the module, Press S2 and release.