NETWORK INTERFACE MODULE (NetNIM)
6.4.1 DETECTOR SETTING
For this alignment use a DC voltmeter with a 0.001V resolution.
1.Measure the voltage between TP34 and TP36.
2.Adjust R93 for 0V ±0.005V.
3.Check U31, pins 1 and 2 for < 0.8V.
4.Measure the voltage between TP33 and TP35.
5.Adjust R75 for 0V ±0.005V.
6.Check U31, pin 13 and 14 for < 0.8V.
7.Check U37, pin 6 for, 0.8V.
INJECTOR/
EXTRACTOR
MASTER/SLAVE (YEL)
CLOCK A/B (YEL)
COMPANION CLOCK (GRN)
COMM TO SMM (YEL)
ALARM (RED)
POWER (GRN)
INJECTOR/
EXTRACTOR
Figure