LOGGING ENCODER MODULE (LEM)

Main Transmit

1.Determine the maximum level to be received by the ancillary equipment to be transmitted.

2.Set S5 for Test 1 (open section 1, close sections 2, 3 and 4).

3.Reset the module, Press S2 and release.

4.Adjust R44 for -12 dB from the maximum level in Step 1 at J12.

5.Set S5 for Test 8 (open section 4, close 1, 2 and 3).

6.Reset the module, Press S2 and release.

7.Adjust R86 to be -3 dBm ±0.5 dB at TP4.

8.Verify the level at J12 to be -12 dB ±1 dB from the maximum level from Step 1.

9.Select for normal operation (S5 all sections closed). 10.Reset the module, Press S2 and release.

Example: Microwave has -16 dBm max input, set

J12 for -28 dBm.