SYSTEM RACK

Table 4-14 PCM CABLE LOCATION

From

To

Shelf 1 - J25

Shelf 1 - J26

Shelf 1 - J5

Shelf 2 - J3

Shelf 1 - J6

Shelf 2 - J4

Shelf 1 - J23

Shelf 2 - J25

Shelf 1 - J24

Shelf 2 - J26

Shelf 2 - J5

Shelf 3 - J3

Shelf 2 - J6

Shelf 3 - J4

Shelf 2 - J23

Shelf 3 - J25

Shelf 2 - J24

Shelf 3 - J26

Shelf 3 - J5

Shelf 4 - J3

Shelf 3 - J6

Shelf 4 - J4

Shelf 3 - J23

Shelf 4 - J25

Shelf 3 - J24

Shelf 4 - J26

Shelf 4 - J5

Shelf 5 - J3

Shelf 4 - J6

Shelf 5 - J4

Shelf 4 - J23

Shelf 5 - J25

Shelf 4 - J24

Shelf 5 - J26

Shelf 5 - J5

Shelf 6 - J3

Shelf 5 - J6

Shelf 6 - J4

Shelf 5 - J23

Shelf 6 - J25

Shelf 5 - J24

Shelf 6 - J26

Table 4-15 S1 SWITCH SETTINGS

Shelf Number

Switch 1, Open Sections

1

ALL Closed

2

1

3

2

4

1,2

5

3

6

1,3

7

2,3

8

1,2,3

9

4

10

1,4

11

2,4

12

1,2,4

13

3,4

14

1,3,4

15

2,3,4

16

1,2,3,4

17

5

18

1,5

Shelf S1 Switch Settings

Verify switch settings of S1 in Table 4-15for each shelf address (see Figure 4-5).

Backplane Switch Settings

Verify the backplane switch settings for S2 - S8 on each shelf are set as follows:

Shelf 1-6 sections 2,5,6,7,8 closed sections 1,3,4 open

PTM Switch Settings

Verify the switch settings of the Power Termination Module (PTM) are as follows:

S5, S7 sections 2,5,6,7 closed; sections 1,3,4 open

S6, S8 sections 2,5,6 closed; sections 1,3,4,7,8 open

Call Processor Connection To Switch

Verify the Call Processor connection to the System rack as follows:

1.NetIDB Connection: Use the 20’ RS-232 cable to connect Shelf 1-J100 to Port 1 of the Call Processor computer.

2.NetCSB Connection: Use the 20’ RS-232 cable to connect Shelf 1-J101 to Port 2 of the Call Processor computer.

3.Install a Power Termination Module in the first slot on the left side of each shelf.

4.Install the NetNIM in Shelf 1, Slot 0.

5.Turn "On" both Power Supplies, turn "On" the Call Processor and note that the four LEDs on each PTM card are "On".

a.Verify that the Call Processor comes up in the Switch mode.

b.Verify that the Call Processor displays the Net- NIM’s clock status, “A Pass B Pass” in the Call

4-15