CHANNEL INTERFACE MODULE (CIM)
Figure5.Adjust R41 to be
6.Select for normal operation (S5 all sections closed).
7.Reset the module, Press S2 and release.
Example: Microwave has +7 dBm max output. Apply
Secondary Transmit
1.Determine the maximum level to be received by the ancillary equipment to be transmitted.
2.Select Test 8 (S5, open section 4, close 1, 2 and 3).
3.Reset the module, Press S2 and release.
4.Adjust R90 for
5.Select for normal operation (S5 all sections closed).
6.Reset the module, Press S2 and release.
Example: Microwave has
Secondary Receive
1.Determine the maximum transmit level that is sent by the ancillary equipment to the interface module.
2.Select Test 8 (S5, open section 4, close sections 1, 2 and 3).
3.Reset the module, Press S2 and release.
4.Insert an alignment tone
5.Adjust R102 to be
6.Select for normal operation (S5 all sections closed).
7.Reset the module, Press S2 and release.
Example: Microwave has +7 dBm max output. Apply