10Drain Pump Connection

CONNECTING A DRAIN PUMP

If a gravity drain connection is not available, and you have not purchased the E15IM60E with factory installed pump, we strongly recommend the use of the Electrolux EIMP60 drain pump. The Electrolux EIMP60 drain pump is available through your Dealer, or direct from Electrolux with complete installation instructions. If a pump other than the Electrolux EIMP60 drain pump is to be used, it must meet the following specifications:

It must be UL listed and have a UL listed, 120 VAC, 3-wire grounded power cord.

It must have overall maximum outside dimensions of 8-3/4" wide x 5-3/4" deep x 7-3/4" high.

It must have a minimum flow rate of 15 gallons per hour at 10 feet of lift.

It must have a sealed sump which does not allow water leakage in the case of a power outage, restricted drain or pump failure.

It must have a check valve in the discharge line to prevent waste water return to the pump.

It must have an overflow protection control which will shut off power to the ice maker in the event of a pump failure.

It must have an operating temperature range of 50°F to 110°F (10°C to 43°C).

!CAUTION

In the event of a power outage, restricted drain or pump failure, the failure to use the Electrolux EIMP60 drain pump or a pump with the above listed specifications, could result in substantial water leakage and pooling with severe and costly water damage and related consequential damages and harm.