Emerson manual Configuration Examples, Rosemount 3051S, Reference Manual, Parameter, pressure

Models: 3051S

1 32
Download 32 pages 28.03 Kb
Page 11
Image 11
Configuration Examples

Reference Manual

00809-0200-4801, Rev BA April 2007

Rosemount 3051S

Configuration Examples

Pressure transmitter

Table 3-2. Analog Input function block configuration for a typical pressure transmitter.

Situation #1

A pressure transmitter with a range of 0 – 100 psi.

Solution

Table 3-2 lists the appropriate configuration settings.

.

Parameter

Configured Values

 

 

L_TYPE

Direct

XD_SCALE

Primary_Value_Range

 

 

OUT_SCALE

Primary_Value_Range

Channel

1 - pressure

 

 

Pressure transmitter used to measure level in an open tank

Figure 3-1. Situation #2

Diagram.

Situation #2

The level of an open tank is to be measured using a pressure tap at the bottom of the tank. The maximum level at the tank is 16 ft. The liquid in the tank has a density that makes the maximum level correspond to a pressure of 7.0 psi at the pressure tap (see Figure 3-1).

16 ft

Full Tank

7.0 psi measured at

the transmitter