Reference Manual
Rosemount 3051S
Configuration Examples
Pressure transmitter
Table
Situation #1
A pressure transmitter with a range of 0 – 100 psi.
Solution
Table
.
Parameter | Configured Values |
|
|
L_TYPE | Direct |
XD_SCALE | Primary_Value_Range |
|
|
OUT_SCALE | Primary_Value_Range |
Channel | 1 - pressure |
|
|
Pressure transmitter used to measure level in an open tank
Figure
Diagram.
Situation #2
The level of an open tank is to be measured using a pressure tap at the bottom of the tank. The maximum level at the tank is 16 ft. The liquid in the tank has a density that makes the maximum level correspond to a pressure of 7.0 psi at the pressure tap (see Figure
16 ft
Full Tank
7.0 psi measured at
the transmitter