3.0OPTIONS

Options

3.0OPTIONS

3.1Remote Alarm Unit

A remote alarm panel is available for displaying important individual UPS messages. The length of the connection cable must not exceed 1000ft.

3.2MopUPS Shutdown and Monitoring Software

The MopUPS Professional software package provides safe system shutdown and power management. With advanced features such as network shutdown, scheduled shutdown and restart, event messaging, event logging, data logging, real time viewing, UPS diagnostics and remote access, MopUPS has everything necessary for preserving data and maximizing system uptime.

The software features:

1.Remote management

Site power and UPS status information can be accessed securely from any computer on your IP- based network. View event history and voltage logs for trend analysis. View UPS system status in real time for situational decision support. Access is based on User Authentication with 128-bit, MD5 encryption.

2.Remote messaging

Keeps you informed anywhere -- fault and recovery messages are sent via SNMP Trap or e-mail. Body of e-mail will include URL for quick link back to UPS Web page. Many pager systems will forward e-mail to your wireless pager - so you can be informed anywhere.

3.Safe system shutdown

Preserves data integrity and minimizes recovery delays with automated system shutdown. MopUPS monitors the UPS for power failure, low battery, or other events that jeopardize com- puter power -- and initiates controlled system shutdown.

While it is always possible to use a serial connection, Emerson recommends employing a ManageUPS network SNMP adapter for communication between MopUPS Professional and Liebert NX so that multiple Server Systems can communicate with the UPS via Ethernet.

With Liebert NX in redundant parallel configuration, MopUPS P/R Edition monitors all the connected Liebert NX units simultaneously. It acquires load data, estimated capacities, and other measurements from individual modules, and groups them together according to whether the system is serial or parallel-redundant and whether it is centralized or parallel-distributed (with or without redundancy). This special edition of MopUPS can analyze module-specific conditions and report situations that may affect redundancy or power margin.

ManageUPS Net Adapter is required when using MopUPS P/R Edition. For more details, see http://connectivity.Emersonpower.com/