Troubleshooting Checklist
Table
Problem | Possible Cause | Recommended Action |
|
|
|
Cannot contact | IP address not assigned. | Refer to the MATRIX E7 Series and |
the |
| SmartSwitch 6000 Series Modules Local |
through |
| Management User’s Guide for the IP address |
management. |
| assignment procedure. |
|
|
|
| Port is disabled. | Enable port. Refer to the MATRIX E7 Series |
|
| and SmartSwitch 6000 Series Modules Local |
|
| Management User’s Guide for instructions |
|
| to enable/disable ports. |
|
|
|
| No link to device. | 1. Verify that all network connections |
|
| between the network management station |
|
| and the |
|
| 2. If the problem continues, contact |
|
| Enterasys Networks for technical support. |
|
|
|
Port(s) goes into | Loop condition detected. | 1. Verify that Spanning Tree is enabled. |
standby for no |
| Refer to MATRIX E7 Series and |
apparent reason. |
| SmartSwitch 6000 Series Modules Local |
|
| Management User’s Guide for the |
|
| instructions to set the type of STA. |
|
| 2. Review the network design and delete |
|
| unnecessary loops. |
|
| 3. If the problem continues, contact |
|
| Enterasys Networks for technical support. |
|
|
|
User parameters | 1. Position of Mode switch | 1. Reenter the lost parameters as necessary. |
(IP address, | (7), NVRAM Reset, was | Refer to MATRIX E7 Series and |
Device and | changed sometime | SmartSwitch 6000 Series Modules Local |
Module name, | before either cycling | Management User’s Guide for the |
etc.) were lost | power or pressing the | instructions to configure the device |
when the | RESET button, causing | through Local Management. |
the | 2. If the problem continues, contact | |
was cycled or the | parameters to reset to | Enterasys Networks for technical support. |
front panel | factory default settings. |
|
RESET button | 2. Clear NVRAM was set |
|
was pressed. | through Local |
|
| Management. |
|
|
|
|