2.2.4 CONFIGURING THE SERIAL INTERFACE (OBSOLETE)

2.2.4.1 JUMPER SETTINGS (OBSOLETE)

The serial data interface between the control system and the NV3128 can be either RS-422A or RS-232. For the newer Universal Control module, the serial interface ports are set up using UniDiag. For the older Command Interpreter, jumpers on the Command Interface Module select parameters appropriate to the chosen protocol.

To select the protocol for data interchange with the obsolete Command

Interpreter, set jumpers on the module as shown in the following table.

RS-422A/RS232 SELECT - J203

RS-422A

RS-232

 

 

1-9

9-17

 

 

2-10

10-18

 

 

3-11

11-19

 

 

4-12

12-20

 

 

5-13

13-21

 

 

6-14

14-22

 

 

7-15

15-23

 

 

8-16

16-24

 

 

DCE/DTESELECTJ284

DCE

DTE

 

 

1-5

5-9

 

 

2-6

6-10

 

 

With all other jumpers in the RS232 position, J295 and J296 select

DCE or DTE operation.

NV3128 RS-422A Machine-Control Routing Switch