CHAPTER TWO - INSTALLATION
CAUTION: THE FOLLOWING INSTALLATION PROCEDURES ARE INTENDED FOR QUALIFIED SERVICE PERSONNEL ONLY. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPER- ATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO. REFER ALL INSTALLATION AND SERVICE TO QUALIFIED PER- SONNEL.
2.1 HARDWARE INSTALLATION
The following discussion makes frequent reference to Fig 2.1
The NV3128 installs in a
1.Using the 2MM allen key supplied, remove the doors and vanity ear covers from the front of the frames.
2.For installation in a telco style rack, reverse the front mounting flanges on the frame prior to bolting the frame into the rack.
3.Lift the frame into the rack, and secure the frame to the rack by the front mounting flanges using rack screws (not supplied).
4.Replace the doors on the front of each frame.
5.Operate the ejector/injector tabs on each of the active circuit modules to disconnect them from the backplanes. Leave the modules partially inserted in the card guides, but electrically disconnected.
CAUTION: THE SETTING OF JUMPER J1 ON EACH POWER SUPPLYASSEMBLY MUST MATCH THE VALUE OF THEAPPLIED AC INPUT VOLTAGE OR DAMAGE TO THE EQUIPMENT MAY RESULT.
6.Unscrew its captive latch and remove the
7.
NV3128 |