10. Removing the Rubber Cap

I

Stylus Color service Manual

Adjustments

4. In Figure 4-8, the vertical position is correct when both the magenta line and the black line are

aligned [as in position OK (0)]. If the vertical position is correct, turn off the printer.

If the black and magenta lines are not aligned, perform the vertical adjustment as described in

steps 5-10.

■ 

The number shown in the sample indicates the thickness level compared with the

current

linear spacer (see step 5), and the linear spacer is prepared with 11 kinds.

 The linear spacer is fixed by two pieces at both sides of the base head. For this reason,

when you replace the linear spacer, replace the two linear spacers at the same time,

■ 

When replacing the linear spacer, place it under the angular spacer.

If necessary, replace the spacer linear. For instance, if your pattern is similar to the pattern shown

under -2, replace the spacer linear with a thinner linear spacer. If your pattern is similar to the

pattern shown under 2, replace the spacer linear with a thicker spacer.

5. Turn the printer off at once.

6. Move the carnage to the center while pressing the carriage lock lever, and remove the two ink

cartridges.

7. Remove the rubber cap that coveringa head screw at a side of color i.nkcartridge and then

Ioosen(but  do not remove) three screws.(Refer to figure below.)

Figure 4-10. Removing the Rubber Cap

After replacing the spacer, always install new ink cartridges before returning the printer to

the user. At this time, use the ink cartridges that are exclusive for service (Monochrome:

1020626

1 

CMY: 1020627). 

You 

can 

re-use the old ink cartridges for otherpurposes.

I

4-10

Rev. D

Page 90
Image 90
Open full-size image