| Interface Specifications |
|
|
|
|
|
|
|
|
Signal | Return | Signal |
| Direction | Description | ||
Pin | Pin |
| |||||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
11 | 29 | BUSY |
| OUT | A HIGH signal Indicates that the printer | ||
|
|
|
|
|
|
| cannot receive data. The signal goes |
|
|
|
|
|
|
| HIGH in the following cases: |
|
|
|
|
|
|
| 1) During data entry (ea. char. time) |
|
|
|
|
|
|
| 2) During printing |
|
|
|
|
|
|
| 3) When the PAUSE button is pressed |
|
|
|
|
|
|
| 4) During an error state. |
|
|
|
|
|
|
|
|
12 | 30 | PE |
| OUT | A HIGH signal indicates that the printer | ||
|
|
|
|
|
|
| is out of paper. |
|
|
|
|
|
|
|
|
13 |
| SLCT |
| OUT | Pulled up to 5 V through 3.3 Kohm | ||
|
|
|
|
|
|
| resistance. |
|
|
|
|
|
|
|
|
14 |
|
|
|
|
| IN | When this signal is LOW, the paper IS |
| AUTO |
| |||||
|
| FEED |
|
| automatically fed one line after printing. | ||
|
| XT |
|
| (The signal level can be fixed to this by | ||
|
|
|
|
|
|
| setting DIP switch |
|
|
|
|
|
|
|
|
15 |
| NC |
|
| Not used. | ||
|
|
|
|
|
|
|
|
16 |
| GND |
|
| Logic ground level. | ||
|
|
|
|
|
|
| |
17 |
| C H A S S | I S - | Printer’s chassis ground, which is | |||
|
| GND |
|
| isolated from the logic ground. | ||
|
|
|
|
|
|
|
|
18 |
| NC |
|
| Not used. | ||
|
|
|
|
|
|
|
|
- | GND |
|
| ||||
|
|
|
|
|
|
|
|
31 | 16 | INIT |
| IN | When this level becomes LOW, the | ||
|
|
|
|
|
|
| printer controller is reset to its |
|
|
|
|
|
|
| state and the print buffer is cleared. This |
|
|
|
|
|
|
| level is normally HIGH; its pulse width |
|
|
|
|
|
|
| must be more than 50 microseconds at |
|
|
|
|
|
|
| the receiving terminal. |
|
|
|
|
|
|
|
|
32 |
|
|
|
| OUT | This level becomes LOW when the | |
| ERROR |
| |||||
|
|
|
|
|
|
| printer is: |
|
|
|
|
|
|
| 1) in a |
|
|
|
|
|
|
| 2) when the PAUSE button is pressed |
|
|
|
|
|
|
| 3) in an error state. |
|
|
|
|
|
|
|
|
Technical Specifications |