Interface Specifications

Interface timing

The figure below shows the timing for the parallel interface.

Signal level: TTL compatibleSerial interface

The printer’s resident serial interface can be set for either RS-232C or E-422operation. These interfaces have the following characteristics:

Data format

 

Word length:

7 or 8 bits

Parity:

none, odd, or even

Stop bits:

1 or 2

Printer ready protocol: enabled (DTR and XON/XOFF protocol set to ON.)

You can set the data format using options and menu items in SelecType.

Appendix A A-11