VIPER Technical Manual | Connectors, LEDs and jumpers |
|
|
LCD supply voltage – LK8 on JP2
This jumper selects the supply voltage for the LCD logic supply.
LK8 DescriptionSupply LCD logic with 5V.
Default setting:
Supply LCD logic with 3.3V.
If the LCD requires a 5V supply, please refer to the LCD datasheet to ensure that the display is compatible with 3.3V logic.
Battery jumper – LK9 on JP4This jumper connects the battery to the battery
Battery is connected to the board |
|
circuit. | Default setting: |
|
Battery is disconnected from board circuit
The battery is disconnected when board is shipped. If battery back up is required, jumper LK9 must be fitted to JP4 before installation of the VIPER.