VIPER Technical Manual | Detailed hardware description |
|
|
Supported on Channel 0 of an external Exar XR16C2850 with 128bytes of Tx and Rx VL FIFOs, and buffered to RS232 levels with ±15kV ESD protection. The maximum baud
rate on this channel is 115.2kb/s. On special request this can be increased to
921.6kb/s. Please contact Eurotech Ltd (see Appendix61H62H63H367HA – Contacting Eurotech, page
COM5 – RS422/485 interfaceSupported on Channel 1 of an external Exar XR16C2850 with 128bytes of Tx and Rx VL FIFOs, and buffered to RS422/485 levels with ±15kV ESD protection, to provide
support for RS422 (default) and RS485 (jumper selectable) interfaces. The maximum baud rate on this channel is 115.2kb/s. On special request this can be increased to
921.6kb/s. Please contact Eurotech Ltd (see Appendix64H65H66H369HA – Contacting Eurotech, page
RS422The RS422 interface provides
To enable RS422 operation, LK667Hand LK7 should be in position for RS422
This is a
The VIPER uses the RTS signal to control transmission. When this signal is at logic ‘1’ the driver is switched off and data can be received from other devices. When the RTS line is at logic ‘0’ the driver is on. Any data that is transmitted from the VIPER is automatically echoed back to the receiver. This enables the serial communications software to detect that all data has been sent and disable the transmitter when required. LK669Hand LK7 should be in position RS485
interface. See RS485/42270Hconfiguration – LK4, LK5, LK6 and LK7, page 99372H, for details. The UART used on the VIPER for COM5 has extended features including
LK471Hand LK5 provide parallel line termination resistors and should be made if the VIPER is at the end of the network.
The RS422/485 cable shield MUST be connected between TITAN J1 pin 9 (GND) and the ground connection of the connecting equipment. Failure to do so can result in TITAN RS422/485 transceiver being permanently damaged.
© 2007 Eurotech Ltd Issue E | 65 |