VIPER Technical Manual

Detailed hardware description

 

 

The general-purpose inputs are 5V tolerant, and the outputs can sink and source up to 24mA @ 3.3V.

OUT0B is an inverted OUT0 signal, and is driven to 3.3V, which provides compatibility with the VIPER-UPS.

The following general purpose IO lines are used by the VIPER-UPS:

Function

IO

External Power Fail

IN0

Battery Low

IN1

UPS Power down

OUT0B

 

 

VIPER-I/O

The VIPER-I/O is a low cost add-on I/O module for the PXA255 board VIPER. The board provides a variety of I/O features without the additional costs of a full PC/104 interface. Please refer to the VIPER-I/O Technical Manual on the Development Kit CD.

© 2007 Eurotech Ltd Issue E