CTRL IN![]()
GND![]()
Idle state
CTRL IN![]()
GND![]()
Playback
2.Record: The input switches to Record (or Record Standby) as long the contact is closed.
CTRL IN![]()
GND![]()
Idle state
CTRL IN![]()
GND![]()
Record / Record Standby
3.Armed / Disarmed: If the contact is closed, the DVR will switch off alarm (alarm contact and motion alarm) operation. System alarm events are always active.
CTRL IN![]()
GND![]()
DVR armed
CTRL IN![]()
GND![]()
DVR disarmed
2.3.3Alarm Output Relay
The relay outputs provide either Normally Open or Normally Closed dry contacts.
Output relay in idle state
2.4 RS-485 keyboard / PTZ Installation
All functions can be