Auto Lock: Check the box and the events will be recorded in the write protected segment of the Hard Disk. (DVR will lock a period of time when alarm happen, the length of time will depend on DVR setting)

Alarm Output: This will transmit a signal through one of the alarm outputs. It can be set to either “NONE” (not active), “1”, “2”, “3”, or “4”.

Output Type: Output action when motion is triggered.

Timeout: Alarm output lasts for the set time duration.

Permanent: Alarm will remain on until user presses “Enter” key on front panel.

Transparent: Alarm output continues as long as there is a motion event.

Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration. Timeout Duration: Time duration selectable from 1 to 150 seconds.

Edit Motion Grid: Press this button to edit the motion grid (See Figure 5-5 Camera Menu – Motion Grid Setting ). Sensitivity: Set the threshold value for sensitivity. Select from 1 (lowest) to 10 (highest).

Min Area: To avoid false detections by small objects this value defines, how many grids have to be detected for generating a motion event. Select a value between 1 (default) to 5 grids.

Delay: Filter function for avoiding false alarms (set to 1 for the easiest trigger)

Preview: Turn off display for motion grid

Set All: Press this button to select the entire area.

Clear All: Press this button to clear all the grids selected.

Save & Back: Press this button to save the motion grid setting and return to motion setting menu.

Cancel: Press this button to cancel all changes and return to motion setting menu. How to select motion grid by mouse:

1.Select left-up grid 2. Select right-down grid. 3. The area between left-up and right-down grid will be selected.

49

Page 56
Image 56