Extron electronic CS 120P Route the cables through the cover plate, Using a flexible conduit

Models: CS 1226T CS 26T CS 120P

1 33
Download 33 pages 50.04 Kb
Page 12
Image 12
8.Route the cables through the cover plate —
Flexible Conduit Adapter
Flexible Conduit
Cover Plate
Seismic Cable Pass
Through Loop
Rear of Speaker
Figure 6. Routing the Cables through the Cover Plate Using a Flexible Conduit
Using speaker wires without a conduit:
a. Secure the cable clamp adapter (included) to the cover plate.
b. Insert the wires through the clamp and cover plate, as shown in figure 7. c. Tighten the clamp screws.
Cable Clamp Adapter
Cover Plate
Seismic Cable Pass
Through Loop
Rear of Speaker
Figure 7. Routing the Cables Without a Conduit
CS 26T and CS 120P User Guide • Installation

8.Route the cables through the cover plate

 NOTES: NOTES:

The CS 120P is fully UL 2043 compliant only when it is used with a metal conduit or with plenum rated cables.

Installation of all conduits, conduit adapters, wiring, and electrical connections must conform to all applicable building codes and local ordinances.

Using a flexible conduit:

a.Route wires through the conduit.

b.Insert the conduit into the cover plate opening using an appropriate conduit adapter, and secure the conduit to the plate as shown in figure 6.

c.Pull the wires out of the conduit and through the cover plate.

6