Advanced menu

Advanced menu

Figure 14 is a flowchart that shows an overview of the Advanced menu and the available settings.

Power

Default

 

on

Cycle

 

 

 

 

Menu

 

10

 

 

sec.

Switch

 

 

 

 

Effect

 

10

Menu

 

 

 

sec.

Output

 

 

 

 

Config

 

10

Menu

 

 

 

sec.

Slide

 

 

 

 

Show

 

10

Menu

 

 

 

sec.

Advanced

Next

 

Menu

 

10

Menu

 

 

 

sec.

Exit

 

Menu

 

Menu

 

 

 

 

Menu

10 sec.

Menu

3 sec.

 

 

10 sec.

 

{scroll}

 

 

 

Auto Sw

Next

Name

 

Name

Next

 

 

 

 

 

Off

 

 

GSS-100-

 

 

nn-nn-nn

 

 

 

 

 

 

Name (Display Only)

 

 

 

 

 

(Changeable under RS-232/Ethernet control;

 

Auto Switch

scrolls to the left if greater than 8 characters.)

Off

Off/show

 

 

 

 

 

 

On/still

On/show

 

 

 

 

 

 

 

 

 

 

 

Menu

 

 

 

Menu

 

 

 

 

 

 

nn:nn:nn Next

Int Temp

Next

 

 

 

 

 

nn:nn:nn

 

 

113F 45C

 

 

 

 

 

MAC Address

 

Temperature

 

 

 

 

 

(Display Only)

 

(Display Only)

 

Menu

 

 

 

 

 

Menu

 

 

 

RS-232

Next

 

 

I192.168

Next

 

 

9600

 

 

 

 

P254.254

 

 

Baud Rate

TAKE

Press Take to

2400

19200

 

enable changing

4800

38400

 

the value.

9600

115200

 

Rotate Adjust/

 

 

 

 

 

Select to change

the value.

TAKE

Press Take to enable

 

changing the value

 

and select an octet.

Rotate Adjust/Select to change the value in the selected (blinking) octet.

Figure 14. Advanced Submenu Flowchart

Auto Switch (and slide show) submenu

The GSS can be set to an auto-switch mode that monitors the sync signal on the RGB pass- through input and automatically switches to the last-displayed stored image or slide show for output when sync is lost. This submenu also allows you to turn the auto-switching and slide show on and off.

Rotate the Adjust/Select mode while in the Auto-Switch submenu to select:

zzOff (auto-switch mode off and slide show off) — Deactivates the automatic sync detection and the slide show.

zzOff/show (auto-switch off and slide show on) — Leaves the automatic sync detection off and manually initiates the slide show. If the pass-through input was being displayed when this selection is made, the GSS displays the first image alphabetically by file name.

zzOn/still (auto-switch on and slide show off) — Activates the automatic sync detection and auto-switches to the still image. If sync is lost, the GSS switches to the last displayed image that was output and outputs that image until sync is restored or you select another image to display.

zzOn/show (auto-Switch on and slide show on) — Activates the automatic sync detection and auto-switches to the slide show. If sync is lost, the GSS switches to the last-displayed image and begins to cycle through the available images.

The default setting is Off.