Control Tab

Control Tab

Control Page

Click the Control tab to access the Control page (see figure 28).

Figure 28. Control Page

On the Control page, you can set the transition effect (cut or dissolve), mute and unmute the video, and select the dissolve duration (from 0 to 5 seconds, in 0.1-second increments). You can also change the slide show settings, such as:

zzThe duration of each image displayed in the slide show (from 0 to 300 seconds) zz Inclusion of the pass-through input in the slide show

zz Auto Switch mode

zz Off — Auto-switch on loss of pass-through sync and slide show are disabled.

zzOff/show — Auto-switch on loss of pass-through is disabled. Slide show is running.

zzOn/still — On loss of sync on the pass-through input, auto-switch to display the last-displayed image until pass-through sync is restored.

zzOn/show — On loss of sync on the pass-through input, auto-switch to run the slide show until sync on the pass-through input is restored.

GSS 100 Graphic Still Store • HTML Control and IPL File Manager 42