Extron electronic GSS 100 manual Command and Response Table for SIS Commands, Image recall

Models: GSS 100

1 60
Download 60 pages 34.24 Kb
Page 28
Image 28
Command and Response Table for SIS Commands

Command and Response Table for SIS Commands

Command

ASCII Command

Response

Additional description

 

(Host to Unit)

(Unit to Host)

 

Image recall

 

 

 

Recall an image to buffer

EX!RF}

CimX!]

Select image X! to display.

Image recall NOTE: It takes several seconds between the issuance of the recall command (EX!RF}) and the receipt of the Cim response.

Show the image that is

ERF}

X!]

The buffer is loaded with image X!.

currently displayed

 

 

 

Take

%

Tke]

Swap the displayed and buffered images using the

 

 

 

selected effect (cut or dissolve).

Switch effect

Set the effect to cut

9*0#

Set the effect to dissolve

9*1#

Read the effect

9#

Set the dissolve duration

10*X##

Read the dissolve duration

10#

Eff0]

Set the effect for switching images to cut (immediate).

Eff1]

Set the effect for switching images to dissolve.

X@]

 

DurX#]

Set the duration of the dissolve effect to X#.

X#]

The dissolve duration is X#.

Source selection

Display pass-through

1!

Chn1]

Display the pass-through input.

Display last image

0!

Chn0]

Display the previously selected stored image.

View pass-through status

!

X@]

Pass-through mode is X@.

Slide show interval

Set slide show interval

2*X##

SliX#]

Set the display time for each image to X# seconds.

Read slide show interval

2#

X#]

The display time for each image is X# seconds.

Pass-through configuration

Enable pass-through

1*1#

Pas1]

Include the pass-through input in the slide show.

Disable pass-through

1*0#

Pas0]

Do not include the pass-through input in the slide show.

Read the pass-through status

1#

X@]

Show the status of the pass-through.

Auto-switch and slide show mode

Set auto-switch and slide

4*X$#

AutX$]

Set auto-switch and slide show mode. X$ definitions:

show mode

 

 

0 = Off — Auto-switch on loss of pass-through sync

 

 

 

and slide show are disabled.

 

 

 

1 = Off/show — Auto-switch on loss of pass-through

 

 

 

is disabled. Slide show is running.

 

 

 

2 = On/still — On loss of sync on the pass-through

 

 

 

input, auto-switch to display the last-

 

 

 

displayed image until pass-through

 

 

 

sync is restored.

 

 

 

3 = On/show — On loss of sync on the pass-through

 

 

 

input, auto-switch to run the slide

 

 

 

show until sync on the pass-through

 

 

 

input is restored.

Show auto-switch and slide

4#

X$]

 

show mode

 

 

 

NOTE: X! = Image file name

Image name with file extension (*.bmp or *.jpg)

X@ = Cut / dissolve status:

0 = cut

1 = dissolve

Pass-through status:

0 = pass-thu

1 = no pass-thru

X# = Time (duration)

00 – 50 (0.0 to 5.0 seconds) for dissolve duration

 

 

000 – 300 seconds for slide show interval

X$ = Auto-switch / slide show

0 = off

2 = on / still

 

 

1 = off / show

3 = on / show

GSS 100 Graphic Still Store • Programming Guide 22

Page 28
Image 28
Extron electronic GSS 100 manual Command and Response Table for SIS Commands, Image recall, Switch effect, Source selection