Extron electronic GSS 100 manual Name display, MAC Address display, Internal Temperature display

Models: GSS 100

1 60
Download 60 pages 34.24 Kb
Page 21
Image 21
Name display

Name display

The read-only Name display shows either the factory default name or a customized name that can be assigned under RS-232 or Ethernet control. If the name is greater than eight characters, the display shows the first eight characters of the assigned name and then scrolls the name to the left to display the remaining characters of the name.

The factory default name is the product name (GSS-100-) plus the last three pairs of the MAC address (see the “Programming Guide“ and “HTML Control and IPL File Manager“ sections to assign a name).

MAC Address display

The read-only MAC Address display shows the hardcoded, factory assigned hardware address.

Internal Temperature display

The read-only Internal Temperature display shows the Fahrenheit and Celsius measurements for the GSS temperature.

MAC Address display CAUTION: Temperatures above 150 degrees Fahrenheit (65 degrees Celsius) are potentially damaging to the GSS.

Baud Rate submenu

The Baud Rate menu is read-only without further action. The menu shows the selected baud rate for the RS-232 port of the GSS. The default setting is 9600.

To change the baud rate, press and release the Take button. The baud rate display starts blinking, and can be adjusted by rotating the Adjust/Select knob.

Internal Temperature display NOTE: The baud rate is also selectable using SIS commands (see the “Programming Baud Rate submenu Guide“ section).

IP address submenu

The read-only IP address menu is read-only without further action. The menu shows the IP address of the GSS. The factory default IP address is 192.168.254.254.

To change the IP address, one octet at a time, press and release the Take button. The first (most-significant) octet starts blinking, and can be adjusted by rotating the Adjust/Select knob. Repeatedly press and release the Take button to cycle through the four IP address octets, enabling them for editing, one at a time.

IP address submenu NOTE: The IP address is also selectable using SIS commands or the HTML pages (see

the “Programming Guide“ and “HTML Control and IPL File Manager

sections).

Exit menu

Press and release the Next button while in the Exit menu to return the LCD to the default display cycle.

GSS 100 Graphic Still Store • Operation 15

Page 21
Image 21
Extron electronic GSS 100 Name display, MAC Address display, Internal Temperature display, Baud Rate submenu, Exit menu