The rear panel RS-232 connector (see figure 16) can be connected to the serial port of a host device, such as a computer or control system. Communications with the GSS are via the Extron Simple Instruction Set (SIS).

 

 

Pin RS-232 Function

RS-232

1

Not used

2

Tx

Transmit data

5

1

3

Rx

Receive data

 

 

 

 

4

Not used

9

6

5

Gnd

Signal ground

6

Not used

 

 

7

Not used

 

 

8

Not used

 

 

9

Not used

Figure 16. Remote Connector Pinout

The baud rate for the rear panel RS-232 port can be set to a variety of different rates. The default protocol for the port is as follows:

zz 9600 baud

z

no parity

zz 8-bit, 1 stop bit

z

no flow control