Extron electronic ISS 506 manual Operation, cont’d, Menu system overview

Models: ISS 506

1 184
Download 184 pages 53.83 Kb
Page 32
Image 32

Operation, cont’d

H

Status display — The 16-column by 2-line LCD window displays

 

configuration menus and status information. See “Menu system overview”,

 

below, and “Front Panel Operations”, later in this chapter, for details.

I

Menu button — The Menu button enters and moves through the main menu

 

system in the ISS. See “Menu system overview”, below, and “Front Panel

 

Operations”, later in this chapter, for details.

 

Next button — The Next button steps through the submenus in the ISS menu

 

system. See “Menu system overview”, below, and “Front Panel Operations”,

 

later in this chapter, for details.

J

Adjust [ (horizontal) and Adjust { (vertical) knobs — The Adjust [ and

 

Adjust { knobs change settings when used in conjunction with the menu

 

system or the picture adjustment buttons.

K

Volume knob — The Volume knob changes the attenuation of the audio

 

output on the Program Variable audio output.

NThe Preview Output and the Fixed Program audio output connectors are not affected by the front panel Volume control.

Menu system overview

Figure 3-2shows a flowchart of the main menus in the menu system.

NOn figure 3-2 and all other flowcharts in this chapter, solid lines indicate screen changes initiated by the operator. Dashed lines indicate screen changes that are the result of a timeout function.

Menu button — Press the Menu button to activate the menu system and to scroll through the nine or ten main menus.

Next button — Press the Next button to move between the submenus of a selected main menu, to activate a submenu for viewing or configuration, and to save a selection. Pressing the Next button during input configuration causes the current input’s number and format type to be displayed on the LCD window.

Adjust [ and Adjust { knobs — When a submenu is active, rotate the Adjust [ knob and Adjust { knob to scroll through the submenu options and select a setting.

When one of the picture adjustment buttons is selected, rotate these knobs to change picture settings.

Refer to the flowcharts in this chapter and to specific sections for explanations of the knob adjustments.

NIf you press the Menu button while a main menu is active, the next main menu becomes active.

If you press the Menu button while a submenu is active, the LCD window backs up to display that submenu’s main menu.

NTo return to the default screens, let the switcher remain idle for 30 seconds until the selected screen times out; or press the Menu button until the Exit Menu appears, then press the Next button.

NFrom any menu or submenu, after 30 seconds of inactivity, the ISS saves all adjustment settings and times out to the default LCD display cycle.

3-4 ISS 506 Integration Seamless Switcher • Operation

Page 32
Image 32
Extron electronic ISS 506 manual Operation, cont’d, Menu system overview

ISS 506 specifications

The Extron ISS 506 is an advanced image scaling and processing solution designed for professional AV environments. This innovative device is tailored to meet the demands of modern presentations, conferences, and media showrooms, providing seamless integration and superior image quality.

One of the standout features of the ISS 506 is its impressive scaling capabilities. It can accept a wide range of input resolutions, ensuring compatibility with various AV sources. The device supports input resolutions up to 4K at 60 Hz, making it an ideal choice for high-resolution displays and content. Its advanced scaling technology not only allows for smooth and clear image scaling but also ensures that images look crisp and professional, regardless of the source.

Another notable characteristic is the ISS 506's powerful signal processing capabilities. It incorporates sophisticated algorithms designed to enhance image quality through deinterlacing, noise reduction, and edge enhancement. These features improve the overall visual experience, making it especially valuable for applications requiring high visual fidelity, such as art galleries and corporate boardrooms.

The ISS 506 is equipped with multiple output options, including HDMI, DisplayPort, and analog formats. This versatility allows users to connect to various display technologies without any compromise in quality. The output can be configured to accommodate different resolutions and aspect ratios, ensuring that content is displayed exactly as intended.

Additionally, the device supports advanced features like video wall processing and multi-window display. With the ability to create engaging visual experiences, users can layer multiple video sources and manage them effectively. The intuitive graphical user interface simplifies the process of setting up and controlling these complex display configurations.

In terms of connectivity, the ISS 506 offers numerous inputs, enabling users to connect laptops, cameras, and other media devices. It also features RS-232 and Ethernet control options, allowing for seamless integration with broader AV control systems.

Finally, the Extron ISS 506 is designed for reliability and ease of use, ensuring consistent performance in demanding environments. When combined with its robust feature set, this device stands out as a comprehensive solution for any professional AV application. Whether for live events, corporate meetings, or educational settings, the ISS 506 meets and exceeds the expectations of today's AV professionals.