Extron electronic MAV Plus, 450 Plus manual Special Characters, SIS Programming and Control, cont’d

Models: 450 Plus MAV Plus

1 172
Download 172 pages 77 b
Page 104
Image 104
Special Characters

SISProgramming and Control, cont’d

Command/response table for SIS commands (continued)

Command

ASCII command

Response

Additional

 

(host to switcher)

(switcher to host)

description

NThe Set e-mail recipient (CR) command, sets the recipient for e-mail notifications. To turn e-mail notifications on, you must then set the events that the switcher reports using one of more separate Set e-mail events (EM) commands.

Set e-mail recipient

EX4!,X4@CR}

IprX4@,]

Example:

E72,Jsmith@folklore.netCR}

 

 

 

IprJsmith@folklore.net,]

Read e-mail recipient

EX4!CR}

IprX4!]

NYou must have first set an e-mail recipient for the e-mail account number (X4!), using the Set e-mail recipient (CR) command, before you can assign events to monitor with the Set e-mail events for recipient (EM) command.

Set e-mail events for

 

EX4!,X4#,X4$,X4$, ... ,X4$EM}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

recipient

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IpeX4$,X4$,X4$, ... ,X4$]

 

 

 

 

 

 

 

 

 

 

 

 

 

Response description:

 

Notify what?, inputs 1 - 64 (inputs above the matrix size are always 0)

fans

power supply

Response example (for CrossPoint 450 Plus 6464):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notify failed and fixed

 

 

E-mail input 8 status

 

 

 

Ignore input 16

 

 

 

 

E-mail power supply and fan status

Response:

 

1

0

0

0

0

 

0

 

 

0

 

0

0

0

0

0

0

 

 

0

 

0

 

0

0

0

0

0

0

0

0

0

0

0

0

1

 

 

 

 

 

3, 1

 

1

 

0

 

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input: 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17

 

 

52 53 54 55 56 57 58 59 60 61 62 63 64

 

 

 

 

 

 

 

 

 

Fans

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supplies

 

 

 

Read e-mail events for

 

EX4!EM}

 

 

 

 

 

 

 

 

X4$,X4$,X4$, ... ,X4$]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

recipient

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set DHCP on or off

 

EX4^DH}

 

 

 

 

 

 

 

 

IdhX4^]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read DHCP status

 

EDH}

 

 

 

 

 

 

 

 

 

 

 

X4^]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set serial port parameters

 

EX4&*X4*,X4(,X5),X5!CP} X4*,X4(,X5),X5!]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read serial port parameters

EX4&CP}

 

 

 

 

 

 

 

 

CpnX4&•CcpX4*,X4(,X5),X5!]

 

 

 

 

 

 

 

 

 

 

Set serial port mode

 

EX4&*X5@CY}

 

 

 

 

 

 

CpnX4&•CtyX5@]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NThe front panel Configuration port (X4& = 2) is limited to the RS-232 protocol only.

Read serial port mode

EX4&CY}

X5@]

Set verbose mode

EX5#CV}

VrbX5#]

Read verbose mode

ECV}

X5#]

Read connection’s security

ECK

X5$]

level

 

 

Commit RAM to flash

E1FF}

NvrX5%]

memory

 

 

Check RAM

EFF}

X5%]

Special Characters

The HTML language reserves certain characters for specific functions. The switcher will not accept these characters as part of preset names, the switcher’s name, passwords, or locally created file names.

The switcher rejects the following characters:

{space (spaces are ok for names)} + } ~ , @ = ‘ [ ] { } < > ’ “ semicolon (;) colon (:) \ and ?.

4-22 CrossPoint 450 Plus and MAV Plus Switchers • SIS Programming and Control

Page 104
Image 104
Extron electronic MAV Plus, 450 Plus manual Special Characters, SIS Programming and Control, cont’d