Extron electronic 450 Plus, MAV Plus manual Command/response table for SIS commands continued

Models: 450 Plus MAV Plus

1 172
Download 172 pages 77 b
Page 95
Image 95
Save, recall, and directly write presets
MprX*,Y!,Y@,Y#, ...,Y/]

Command/response table for SIS commands (continued)

Command

ASCII command

Response

Additional

 

(host to switcher)

(switcher to host)

description

Save, recall, and directly write presets

N• If the user tries to recall a preset that is not saved, the matrix switcher responds with the error code E11.

If the room is nonexistent, the matrix switcher responds with the error code E21.

The following characters are invalid in preset names: + ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?.

Save current the current

X1!,

SprX1!]

Command character is a

configuration as a global

 

 

comma.

preset

 

 

 

Example:

9,

Spr09]

Save current ties as preset 9.

Direct write process

 

 

 

NThe direct write of a global preset command should always be preceded by a clear global preset command of that same preset number, as shown below. In a directly-written preset, each output position’s tied input (or no tied output) remains unchanged unless overwritten or cleared.

If you do not clear a global preset number before you directly write a global preset to that number, ties that are part of the previous version of the specified preset can unexpectedly become part of the newly-created preset.

Clear a global preset

E+X1!P0*!}

SprX1!]

Clear all ties in preset X1!.

Directly write a global

E+X1!PX@*X#!X@*X#%X@*X#$ ... X@*X#&}

Enter as many ties as are

preset

 

 

 

 

 

 

 

 

SprX1!]

valid for this model. The

 

 

 

 

 

 

 

 

 

 

 

tie all (!), tie RGBHV (&), tie

 

 

 

 

 

 

 

 

 

 

 

video (%), and tie audio ($)

 

 

 

 

 

 

 

 

 

 

 

commands are all valid.

Example:

E+27P0*!}

Spr27]

Brackets are shown to

 

 

 

 

 

 

 

 

 

 

 

separate ties for clarity only.

 

E+27P22*5!15*29%13*26$3*8&

 

Create global preset 27,

 

 

 

 

 

 

 

 

 

Spr27]

 

 

 

 

 

 

 

 

 

which ties video and audio

 

 

 

 

 

 

 

 

 

 

 

input 22 to output 5,

 

 

 

 

 

 

 

 

 

 

 

RGBHV input 15 to output 29,

 

 

 

 

 

 

 

 

 

 

 

video input 13 to output 26,

 

 

 

 

 

 

 

 

 

 

 

and audio input 3 to output 8.

Recall a global preset

X1!.

RprX1!]

Command character is a

 

 

 

 

 

 

 

 

 

 

 

period.

Example:

5.

 

 

 

 

 

 

 

RprX1!]

Recall preset 5, which

 

 

 

 

 

 

 

 

 

 

 

becomes the current

 

 

 

 

 

 

 

 

 

 

 

configuration.

Write room outputs

EX*,Y!,Y@,Y#, ..., Y/MR}

 

 

See notes.

N• Each Y` is an output.

A room can contain a maximum of 16 outputs (Y`s).

An output can belong to one room only.

The maximum number of rooms (X*) is 10.

If no room name is assigned, the dafault name is “Room #X*•Y!,•Y@,•Y#”.

Example:E8,3,04,5,6MR} Mpr8,03,04,05,06]

Read room outputs

EX*MR}

X2!,Y!,Y@,Y#, ..., Y/]

Example:

E3MR}

Class 1,01,02,08,09]

Save current configuration

X**X1@,

RmmX*•SprX1@]

as a room preset

 

 

Example:

3*9,

Rmm03Spr09]

Outputs 3, 4, 5, and 6 are assigned to room 8.

Outputs 1, 2, 8, and 9 are assigned to room 3, which is named “Class 1”. Command character is a comma.

Save the current

configuration as preset 9 for room 3.

CrossPoint 450 Plus and MAV Plus Switchers • SIS Programming and Control 4-13

Page 95
Image 95
Extron electronic 450 Plus Command/response table for SIS commands continued, Save, recall, and directly write presets