Figure 5-11 — Ties shown as crosspoints

Figure 5-11 — Ties shown as crosspoints

Frequency read options (systems with a CrossPoint 450 Plus sync BME only) Allows you to set the input signal detection (DSVP) feature as follows:

To never sample and display the sync or no sync status (set this option to None)

To automatically refresh the display

(set this option to Automatically every 10 seconds)

To sample the sync and update the display whenever you make a configuration change (set this option to On demand or by refresh).

Limit ties to same group — Allows you to limit the creation of ties using the program to inputs and outputs that are in the same group (similar to front panel operation).

Icons in I/O boxes — Erases any numbers in the I/O boxes in the Control Program window (figure 5-4). You can place icons in the boxes.

Numbers in I/O boxes — Erases any icons in the I/O boxes in the Control Program window and fills each box with the associated input or output number.

Catch FPC/others changes — When checked, sets the switcher to report all configuration and setting changes to the Remote RS-232/RS-422 or Ethernet connection that turned this selection on. These reports allow the Matrix Switcher Control Program to track the changes that occur in the switcher’s configuration and settings, whether commanded via the front panel, the RS-232/RS-422 port, or the Ethernet port.

Master-Reset selection

Master reset clears all ties and presets, all video and audio mutes, resets all I/O grouping, sets all input audio levels to unity gain (+0 dB), and sets all output volume levels to 100% (0 dB of attenuation).

NMaster reset does not reset the Internet protocol (IP) settings.

CrossPoint 450 Plus and MAV Plus Switchers • Matrix Software 5-19