Ethernet Connection
ETHERNET
LINK ACT

Ethernet Connection

Ethernet Link

The rear panel Ethernet connector on the CrossPoint 450 Plus and MAV Plus switcher BMEs can be connected to an Ethernet LAN or WAN. This connection makes SIS control of the switcher possible using a computer connected to the same LAN. Although for normal system

control, the connection is to BME 0, you can connect to and communicate with any BME (for example, you connect to other BMEs to perform a firmware upgrade).

Ethernet connection

The Ethernet cable can be terminated as a straight-through cable or a crossover cable and must be properly terminated for your application (figure A-1).

Crossover cable — Direct connection between the computer and switcher BME (usually BME 0)

Patch (straight-through) cable — Connection of a switcher BME (usually BME 0) to an Ethernet LAN.

Patch (straight) cable

 

 

 

 

 

 

Side 1

 

 

Side 2

 

 

 

 

 

Pin

Wire color

 

Pin

Wire color

 

 

 

 

 

1

White-orange

 

1

White-orange

Side

Clip Down

 

 

 

 

 

 

 

2

Orange

 

2

Orange

 

Pins

1 2 3 4 5 6 7 8

 

RJ-45

 

 

 

 

 

 

 

 

 

 

3

White-green

 

3

White-green

 

 

 

 

 

 

 

 

 

connector

 

 

 

 

 

 

 

 

 

 

4

Blue

 

4

Blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

White-blue

 

5

White-blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Green

 

6

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

White-brown

 

7

White-brown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Brown

 

8

Brown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4 5 6 7 8

1&27&8

3&6 4&5

Crossover cable

 

 

Side 1

 

 

Side 2

 

Pin

Wire color

 

Pin

Wire color

 

1

White-orange

 

1

White-green

Twisted

2

Orange

 

2

Green

Pairs

 

 

 

 

 

3

White-green

 

3

White-orange

 

 

 

 

 

 

 

 

 

4

Blue

 

4

Blue

 

 

 

 

 

 

 

5

White-blue

 

5

White-blue

 

 

 

 

 

 

 

6

Green

 

6

Orange

 

7

White-brown

 

7

White-brown

 

 

 

 

 

 

 

8

Brown

 

8

Brown

Figure A-1RJ-45 connector pinout tables

Default address

To access BME 0 via the Ethernet port, you need the switcher’s IP address. If the address has been changed to an address comprised of words and characters (an alias), you can determine the actual numeric IP address using the Ping utility. If the address has not been changed, the factory-specified default is 192.168.254.254.

Ping can also be used to test the Ethernet link to any CrossPoint 450 Plus or MAV Plus switcher BME.

A-2 CrossPoint 450 Plus and MAV Plus Switchers • Ethernet Connection