Audio output volume

SISProgramming and Control, cont’d

Command/response table for SIS commands (continued)

Command

ASCII command

Response

Additional

 

(host to switcher)

(switcher to host)

description

Audio output volume

NThe table on the next page defines the value of each audio volume step.

NYou can set the output volume to whole dB values only, using the X#*X&V command. The increment and decrement level (X#+V and X#-V) commands increase and decrease the volume in steps of 0.5 dB only. The X& values for all audio output volume commands are reported in whole dB levels only; the reported X& value is rounded up to the next higher magnitude value (for example, 3.5 dB is reported as 4 dB.

Set audio volume to a

X#*X&V

OutX#•VolX&]

 

specific value

 

 

 

Example:

1*50v

Out01Vol50]

Set output 1 volume to 79%.

Increment value

X#+V

OutX#•VolX&]

Increase volume by 0.5 dB.

Example:

1+V

Out01Vol51]

Increment audio volume

 

 

 

0.5 dB, from 79% to 80.5%.

Decrement volume

X#-V

OutX#•VolX&]

Decrease volume by 0.5 dB.

Read output volume

X#V

X&]

 

Audio mute

 

 

 

Audio mute

X#*1Z

AmtX#*1]

Mute audio output X#

 

 

 

(audio off).

Audio unmute

X#*0Z

AmtX#*0]

Unmute audio output X#

 

 

 

(audio on).

Read audio mute

X#Z

X(]

1 = mute on, 0 = mute off.

Global audio mute

1*Z

Amt1]

Mute all audio outputs.

Global audio ummute

0*Z

Amt0]

Unmute all audio outputs.

Names

 

 

 

Write global preset name

EX1!,X2!NG}

NmgX1!,X2!]

 

Example:

E1,Security 1NG}

Nmg01,Security 1]

Name global preset 1

 

 

 

“Security 1”.

Read global preset name

EX1!NG}

X2!]

 

Example:

E2NG}

Security 2]

 

Write room name

EX*,X2!NR}

NmrX*,X2!]

 

Example:

E1,Classrm 1NR}

Nmr01,Classrm 1]

Name room 1 “Classrm 1”.

Read room name

EX*NR}

X2!]

 

Write room preset name

EX**X1@,X2!NP}

NmpX**X1@,X2!]

 

Example:

E1*2,Podium_DVDNP} Nmp01*03,Podium_DVD]

 

 

 

 

Name room 1, preset 3

 

 

 

“Podium_DVD”.

Read room preset name

EX**X2!NP}

X2!]

 

NIf a preset is unassigned, then X2! displays [unassigned].

If a global preset is saved, but not yet named, the default name is Preset•X1!.

If a room preset is saved, but not yet named, the default name is RMX*•PrstX1@.

Write input name

EX!,X2!NI}

NmiX!,X2!]

 

Example:

E1,Podium cam1NI}

Nmi01,Podium cam]

Name input 1 “Podium cam”.

Read input name

EX!NI}

X2!]

 

Write output name

EX#,X2!NO}

NmoX#,X2!]

 

Example:

E1,Main PJ1NO}

Nmo01,Main PJ1]

Name output 1 “Main PJ1”.

Read output name

EX#NO}

X2!]

 

4-10 CrossPoint 450 Plus and MAV Plus Switchers • SIS Programming and Control

Page 92
Image 92