Extron electronic 450 Plus Symbol definitions, X1! =, X1# =, X1$ =, X1% =, X1 =, X1& =, X1* =

Models: 450 Plus MAV Plus

1 172
Download 172 pages 77 b
Page 89
Image 89
Symbol definitions

Symbol definitions

] = CR/LF (carriage return/line feed) (hex 0D 0A)

}= Carriage return (no line feed, hex 0D)

= Space character

E= Escape key (hex 1B)

X!

=

Input number

01

– (maximum number of inputs for your model)

X@

= Input number (for tie)

00

– (maximum number of inputs for your model) (00 = untied)

X#

=

Output number

01

– (maximum number of outputs for your model)

X$

=

Numeric dB value

–18 to +24 (45 steps of gain or attenuation)

X%

=

Audio gain

0

– 24

(1 dB/step)

X^

=

Audio attenuation

1

– 18

(1 dB/step)

X&

=

Volume adjustment range

0

– 64

(1 dB/step except for 0-to-1, which is 34.5 dB)

 

 

 

(see the table on page 4-11)

X*

= Room # (for room presets)

10 max. (each can have up to 10 presets (X1@s) assigned)

N A Room is a subset of operator-selected outputs that relate to each other. The switcher supports up to 10 rooms, each of which can consist

 

 

of from 1 to 16 outputs.

 

X(

=

Mute, executive mode, power supply

(0 = off/not OK, 1 = on/OK)

X1)

=

Group # (for I/O grouping)

1 through 4 groups (0 = no group)

X1! =

Global preset #

64 maximum (0 = current configuration)

X1@ =

Room preset #

10 maximum (0 = current configuration for room)

N A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from memory,

 

it becomes the current configuration.

 

 

X1# =

RGB delay interval

Delay in ½ second increments (10 maximum)

X1$ =

Video/audio mute:

0

= no mutes

 

 

1

= video mute

 

 

2

= audio mute

 

 

3

= video and audio mute

X1% =

Sync frequency

xxx.xx (frequency in Hz (V) or kHz (H))

X1^ =

Signal detection

0

= no input detected, 1 = input detected)

X1& =

Firmware version number to second decimal place (x.xx)

 

 

X1* =

BME type

1

= wideband video

 

 

2

= low resolution video

 

 

3

= Sync

 

 

4

= stereo audio

 

 

5

= Mono audio

X1( =

# of connected BMEs in the system

1 through 6

X2) =

Verbose firmware version-description-upload date/time. See page 4-18.

X2! =

Name

12 characters maximum for global, room preset, input, and output names

 

 

11 characters maximum for room names

 

 

Upper- and lower-case alphanumeric characters and

 

 

_ : = / and spaces are valid.

NThe following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?.

X2@ =

Voltage

Positive or negative voltage and magnitude

X2#

=

Temperature

Degrees Fahrenheit

X2$

=

Fan speed

RPM

CrossPoint 450 Plus and MAV Plus Switchers • SIS Programming and Control