Extron electronic MAV Plus Front Panel Configuration Port, Installation, cont’d, pin D, Connection

Models: 450 Plus MAV Plus

1 172
Download 172 pages 77 b
Page 30
Image 30
Front Panel Configuration Port

Installation, cont’d

Front Panel Configuration Port

m Configuration port — This 2.5 mm mini stereo jack (figure 2-14) serves the same serial communications function as the rear panel Remote port, but it may easier to access. The optional 9-pin D to 2.5 mm stereo mini TRS RS-232 cable, part #70-335-01(figure 2-15) can be used for this connection.

CONTROL

I/O

ESC

AUDIO
VIDEO
POWER SUPPLY
I/O CONFIG

 

PRIMARY
REDUNDANT
CROSSPOINT 450 PLUS SERIES
ULTRA WIDEBAND MATRIX SWITCHER

13

 

Figure 2-14 — Front panel configuration port

6 feet

(1.8 m)

1CONTROLAUDIO 6

9

5

Part #70-335-01

Tip

Ring

Sleeve (Gnd)

9-pin D

Connection
TRS Plug

Pin 2

Computer's RX line

Tip

Pin 3

Computer's TX line

Ring

Pin 5

Computer's signal ground

Sleeve

Figure 2-15 — Optional 9-pin TRS RS-232 cable

NThe maximum distances from the matrix switcher to the controlling device can vary up to 200' (61 m). Factors such as cable gauge, baud rates, environment, and output levels (from the switcher and the controlling device) all affect transmission distance. Distances of about 50' (15 m) are typically not a problem. In some cases the matrix switcher may be capable of serial communications via RS-232 up to 250' (76 m) away.

NThis port is completely separate from the rear panel Remote port and is not affected by changes to the rear panel port’s protocol. This front panel port’s protocol can be changed, under SIS command control only.

This port is RS-232 only, with its default protocols as follows:

9600 baud

• no parity

8-bit

1 stop bit

• no flow control

 

2-12 CrossPoint 450 Plus and MAV Plus Switchers • Installation