Selecting the rear panel Remote port protocol and baud rate

Operation, cont’d

Selecting the rear panel Remote port protocol and baud rate

The switcher can support either the RS-232 or the RS-422 serial communication protocol, and operate at 9600, 19200, 38400, and 115200 baud rates. The settings of these variables can be viewed and changed from the front panel.

View and configure the switcher’s serial communications settings as follows:

1.To enter Serial Port Configuration mode, simultaneously press and hold all Control buttons (Enter, Preset, View, and Esc) (figure 3-67).

Press and hold the Enter, Preset, View, and Esc buttons.

C O N T R O L

C O N T R O L

 

I / O

ENTER

PRESET

VIEW

ESC

2 seconds

ENTER

PRESET

VIEW

ESC

RGBHV

AUDIO

 

 

 

 

 

 

 

 

 

All Control buttons light with one flashing.

 

 

 

 

Both I/O buttons light with one flashing.

 

 

 

 

The flashing Control button indicates the baud rate as follows:

 

 

 

 

Enter — 9600

Preset — 19200

 

 

 

 

View — 38400

Esc — 115200

 

 

 

= Blinking button

The flashing I/O button indicates the protocol as follows:

 

 

 

 

 

 

RGBHV/Video — RS-232

Audio — RS-422/RS-485

 

 

 

 

In this example, the port is set to RS-232 at 9600 baud.

 

 

 

 

Figure 3-67RS-232/RS-422 and baud rate display

 

2.

Release the Control buttons.

 

 

3.To change a value, press and release the button that relates to the desired value (figure 3-68).

Press and release the button(s) to configure the port as

follows:

 

Baud rate:

 

Enter — 9600

Preset — 19200

View — 38400

Esc — 115200

Serial protocol:

 

RGBHV/Video — RS-232

Audio — RS-422/RS-485

The selected buttons blink and the others remain lit.

In this example, the port is set to RS-422 at 38400 baud.

C O N T R O L

ENTER

PRESET

VIEW

ESC

I / O

RGBHV AUDIO

= Blinking button

Figure 3-68RS-232/RS-422 and baud rate selection

4.Press and release an input or output button to exit the Serial Port Configuration mode (figure 3-69).

Press and release an

All Control and I/O buttons return to unlit or background illumination.

input or output button.

 

 

 

 

 

 

 

 

C O N T R O L

 

I / O

 

 

 

 

 

 

 

 

 

 

 

 

 

5

ENTER

PRESET

VIEW

ESC

RGBHV

AUDIO

 

 

 

 

 

 

 

 

Figure 3-69 — Exit Serial Port Configuration mode