CONNECTION OF THE FEEDING CABLE TO THE MAINS

CONNECTION OF THE FEEDING CABLE TO THE MAINS

Connect the feeding cable to a plug suitable for the load indicated on the rating plate of the product. In case of a direct connection to the mains (cable without plug), it is necessary to insert a suitable omnipolar switch before the appliance, with minimum opening between contacts of 3 mm (the grounding wire should not be interrupted by the switch).

Before connecting to the main electrical wiring, make sure:

The electrical counter, the safety valve, the feeding line and the socket are equipped to withstand the maximum load required to run the range. (see rating plate).

The supply system is regularly grounded, according to the local regulation codes.

The socket or the omnipolar switch can easily be reached after the installation of the range.

After carrying out the connection to the main electrical wiring, check the supplying cable does not come into contact with parts subject to heating.

Never use reductions, shunts, or adaptors which can cause overheating or burning.

The manufacturer is not liable for any direct or indirect damage caused by faulty installation or connection. We recommend all installation and connection operations be carried out by qualified personnel complying with the national and local regulation codes.

CAUTION

Connect the black wire to the N (neutral) tab; connect the red wire to the L (live) tab and the green or green/yellow wire to the ground tab. Do not swap connections.

ELECTRICAL SPECIFICATIONS

Model

Volts

Watts

Amps

 

 

 

 

RFA-244 DF

240

2.5 KW

15

 

 

 

 

RFA-365 DF

240

3.55 KW

15

 

 

 

 