SETTING THE MINIMUM FLAME

The flame on the lowest output level is regulated by the factory. When the injectors have been replaced or there are conditions of unusual gas pressure, it may be necessary to regulate a minimum size flame. Please follow the below directions:

Turn the burner knob to the minimum position.

Use a thin blade screw driver to turn the screw located in the brass shaft.

Turn the screw fully clockwise, then turn it counter-clockwise 1/4 turn for the Dual Burner and 1/8 turn for all other burners. The result should be a small, stable flame which is uniform around the entire burner ring. If not, turn the screw counter-clockwise until satisfied with the size of the flame.

Put the knob back on the range and turn it quickly from the maximum position to the minimum position, checking that the flame does not go out.

For burners with safety valves, make sure the regulation obtained is sufficient to maintain heating of the thermocouple. If not, increase the minimum.

THE BURNERS REQUIRE NO REGULATION OF THE AIR FLOW THROUGH OR AROUND THE BURNER. ANY OF THE FOLLOWING ARE CONSIDERED TO BE ABNORMAL OPERATION AND MAY REQUIRE SERVICING:

Yellow tip on the hob burner flame.

Soot buildup on cooking tools.

Burners not igniting properly.

Burners failing to remain lit.

Burners flames extinguished by opening oven door.

Gas valves are difficult to turn.

IN CASE THE RANGE FAILS TO OPERATE CORRECTLY, CONTACT THE SERVICE HOTLINE LISTED ON THE BACK OF THIS MANUAL.

18

Page 18
Image 18
Fagor America RFA-365 DF, RFA-244 DF manual Setting the Minimum Flame