WARNING! DO NOT USE AN OPEN FLAME WHEN CHECKING FOR LEAKS!

Once the range has been installed, make sure the gas pipe is neither crushed or damaged. Before using the range, check all connections for gas leaks with soap and water by pouring the mixture over the gas line and watching for bubbles. If bubbles are visible a gas leak is present and must be repaired before the unit is used.

WARNING! DO NOT USE AN OPEN FLAME WHEN CHECKING FOR LEAKS!

Ignite all burners separately to ensure correct operation of gas valves, burners and ignition. Turn control knobs to low flame position and observe stability of the flame for each burner separately. When satisfied with the operation of the cooktop, please instruct the user on the correct method of operation. In case the cooktop fails to operate correctly after all checks have been carried out, refer to an authorized service provider in your area.

CONVERSION TO DIFFERENT TYPES OF GAS

When converting the range from Universal LPG to Natural Gas, ensure the LPG test point is removed and replaced with the NG Regulator supplied in this kit. The test point pressure must be adjusted to 4”W.C with the largest burner operating on maximum flame.

When converting from Natural Gas to Universal LPG ensure the NG regulator is removed and replaced with the Test Point Assembly supplied in this kit. An approved gas regulator suitable for a supply pressure of 10”W.C should be part of the gas tank supply and the test point pressure must be adjusted to 10”W.C.

To adapt the appliance to a different type of gas from what the range was set up for (see gas type label inside the warming compartment door) proceed as follows:

Remove the burner caps and burner heads.

Using a 7mm socket spanner unscrew/remove the injectors.

Replace the injectors with replacement injectors supplied corresponding to the gas available (see burner and injector characteristics table).

Reattach injectors and replace burner caps and heads.