INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

Electrical Connection

To convert the governor, snap the device out of the top and refit it the other way up. The snap-in converter device is marked to show the gas for which it is set:

Natural gas

 

 

 

 

Propane gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This appliance must be installed by a qualified electrician to comply with the relevant regulations (in particular AS/NZS 60335.2.6:2002), and also the local electricity supply company requirements.

Make sure the device is secure in the top cap and refit the cap to the governor.

Stick on label

Stick the appropriate label on to the data badge to indicate the gas for which the appliance is now set.

Propane Pressure Testing

Connect the appliance to the gas supply. Ensure that the appliance is gas sound.

The gas pressure can be measured at one of the left hand hotplate burner jets. Lift off a burner head. Fit the pressure gauge to the jet. Turn on the hotplate burner and turn on and light one of the other burners.

Re-assemble the burner top, making sure that it is re- assembled in the correct way on the burner body.

Refit the control tap shield. Reconnect the wiring to the control panel and refit the panel.

Check that the appliance is both electrically safe and gas sound.

Check the operation of all the burners.

Ensure that the mains characteristics (voltage, nominal, power, etc.) match the ratings indicated on the data plate affixed to the cooker.

The cooker is preset for a single-phase earthed electrical connection. It is essential to install a multi-pole circuit breaker that completely disconnects the appliance from the mains, with a minimum contact break distance of 3mm.

WARNING: THIS APPLIANCE MUST BE EARTHED

The appliance must be connected to an efficient earthing circuit. If the electricity network is not equipped with an earth connection, then it must be installed separately in compliance with local regulations.

Earthing is a safety measure required by law, and must be performed with particular care by a qualified technician, who must also check that the electricity supply characteristics are correct.

The cable size used should be suitable for the appliance load and in accordance with local regulations. Please note that the maximum cable sizes are 6mm2 for the screw terminals.

Access to the mains terminal is gained by removing the electrical terminal cover box on the back panel. Connect the mains cable to the correct terminals for your electrical supply type.

You may need to move the links to suit your connection type. Check that the links are correctly fitted and that the terminal screws are tight. Secure the mains cable using the cable clamp.