Australia

Technical Data

This cooker is designed for use on Natural Gas, although a conversion for LP (LPG X Propane (2.54kPa)) gas is available.

INSTALLER: Please leave these instructions with the user.

DATA BADGE LOCATION: Cooker back. The serial number is repeated on the badge below the left hand oven door opening.

Country of Destination: Australia

Test Pressures (quoted on the data badge)

Gas

 

 

Electric

 

 

Natural gas

1kPa

 

220 - 240V 50Hz

 

 

Propane

2.54kPa

 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

Overall height

 

 

minimum 893mm

 

maximum 920mm

Overall width

 

 

900mm

 

 

Overall depth

 

 

648mm

 

 

Minimum space above hotplate

 

650mm

 

 

Connections

Gas:

Electric

Rp 1/2 at rear right

220 - 240V 50Hz

Ratings

 

Natural Gas 1.0kPa

 

 

Propane 2.54kPa

 

 

Hotplate

 

Injector

 

Bypass

 

Injector

 

Bypass

 

 

 

 

 

 

 

 

 

 

Input

Marking

Size

Marking

Input

Marking

Size

Marking

 

 

internal 112

1.12mm

 

 

internal 66

0.67mm

 

Wok burner

15MJh-1

external 164

1.65mm

90

15MJh-1

external

0.87mm

54

 

 

 

 

 

 

91

 

 

Large Burner

12.3MJh-1

165

1.65mm

80

12.3MJh-1

89

0.96mm

41

Medium Burners

6.2MJh-1

115

1.15mm

56

6.2MJh-1

67

0.68mm

33

Small Burner

3.7MJh-1

92

0.92mm

48

3.3MJh-1

48

0.50mm

25

 

 

 

 

 

 

 

 

 

Gas burner inputs based on Gross Calorific Value

 

 

 

 

 

Ovens

Left hand Multi-function Oven

Right hand Fan Oven

Fan element

2.5kW

2.5kW

Top element

1.2kW

 

Browning Element

1.15kW

 

Bottom element

1.0kW

 

Grill

2.3kW

 

Maximum total electrical load at 230V 7.4kW (approximate total including oven lights, oven fan etc.).

36

Page 36
Image 36
Falcon U109635-02 manual Technical Data