41
9 Digital Communication InterfaceInterface Commands
CommandDescription
Command
Format
Command
Example Returned
Returned
Example
Acceptable
Values
Stopprogram pc=s[top] pc=s
Continueprogram pc=c[ont] pc=c
Readprogram function pf pf pf:9 pf: 3
Setprogram function to
n
pf=
n
pf=2 1to4
ConfigurationMenu
OperatingParameters Menu
Readhigh limit hl hl hl: 9999 hl:925
Sethigh limit hl=n hl=900 100–1200
Readsoft cutout cuto cuto c: 9999.9 c: 1150.0
Setsoft cutout setting: cu[tout]=n
Setsoft cut-out to
n
degrees cu[tout]=n cu=500 0.0 to 1150.0
Readcut-out mode cm[ode] cm cm:{xxxx} cm:AUTO
Setcut-out mode cm[ode]=r[eset]/a[uto] Resetor Auto
Setcut-out to be reset manually cm[ode]=r[eset] cm=r
Setcut-out to be reset
automatically
cm[ode]=a[uto] cm=a
SerialInterface Menu
Readserial sample setting sa[mple] sa sa: 9 sa:1
Setserial sampling setting to
n
seconds
sa[mple]=
n
sa=0 0to 4000
Setserial duplex mode: du[plex]=f[ull]/h[alf] FULL or HALF
Setserial duplex mode to full du[plex]=f[ull] du=f
Setserial duplex mode to half du[plex]=h[alf] du=h
Setserial linefeed mode: lf[eed]=on/of[f] ONor OFF
Setserial linefeed mode to on lf[eed]=on lf=on
Setserial linefeed mode to off lf[eed]=of[f] lf=of
CalMenu
ReadCT
n
calibrationparameter ct
n
ct1 ct
n
:99.9C ct1:–10.0C
Set CT
n
calibrationparameter to
n
ct
n
=
n
ct1=–10.0 0to 12.00
ReadCE
n
calibrationparameter ce
n
ce1 ce
n
:99.9C ce1: -10.1C
Set CE
n
calibrationparameter to
n
ce
n
=
n
ce1=–10 –99.9to 99.9
Table 3 Communications Commands Summary continued