Continued from previous page.
| When | |
14 | Twice Monthly | |
Tools | ||
| ||
| Digital thermometer with fry | |
| vat probe, 1/8” (3 mm) flat- | |
| ||
| blade screwdriver, Pro Fry | |
| computer. |
2 of 2
© 2000 McDonald’s Corporation All Rights Reserved
Check Calibration (With MACC100, M100A, M100B or M2000 Computer).
12.Note: The computer should rarely be out of the ±5°F (±3°C) range, as it is preset at the factory.
13.Repeat all the above steps for remaining fryers.
Check Calibration (With Thermostat Controller Only)
1.Turn vat ON and set the thermostat knob to the correct cooking temperature.
2.Allow the vat to cycle OFF after reaching the cooking temperature.
3.The cooking oil should be at the normal (upper)
4.Insert the fry vat probe into the cooking oil to within one (1) inch of the fryer
5.Allow the vat to cycle ON and OFF three times.
6.After the stabilizing period, the instant vat cycles ON for the fourth time (as noted by the fryer heat light turning ON) the cooking oil temperature should be within ±5°F (±3°C) of the thermostat setting.
7.If it is within ±5°F (±3°C), calibration is complete.
8.If not, adjustments can be made by:
a.Locating temperature control knob set screw.
b.Using a 1/8" (3 mm)
c.Carefully hold the knob and tighten the setscrew using the 1/8" (3 mm)
9.Repeat Steps 1 through 9 for remaining fryers.