Frymaster BIELA14 Replace filter O-rings, Quarterly FR 3 Q4, 2Remove filter pan, Time of day

Models: BIGLA30 BIELA14

1 26
Download 26 pages 13.97 Kb
Page 22
Image 22
Replace filter O-rings

 

Replace filter O-rings

 

 

 

Quarterly

 

 

 

FR 3 Q4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Why

To keep the fryer’s filter pump in working order

 

 

 

 

 

Time required

2 minutes to prepare

5 minutes to complete

 

 

 

 

 

Time of day

At open; the fryer must be cool

For 24-hour restaurants: During a low-volume period

when the fryer can be turned off

Hazard icons

Tools and supplies

O-rings for the filter

Flat tip screwdriver

No-scratch pad

pump

 

 

Frymaster Fryer Model BIELA14 and BIGLA30 – LOV

Procedure

1Prepare fryer for procedure.

Check to make sure the fryer is cool. This procedure should be done only when the fryer is cool and the filter pan is empty.

2Remove filter pan.

Pull the filter pan out of the cabinet.

3Replace O-ring.

Remove the O-ring from the pan nozzle. Replace the O- ring with a new O-ring. O- rings can be purchased from your local authorized servicer.

Use only the manufacturer’s replacement O-ring. These rings are manufactured spe- cifically for use with hot cooking oils. Generic O-rings cannot be used for this pur- pose.

4Clean pickup tubes.

Clean the male and female pickup tubes with a no- scratch pad.

5Reinstall filter pan.

Reinstall the pan into the fryer cabinet.

Quarterly

FR 3 Q4

©McDonald’s Corporation · Planned Maintenance Manual · Revised June 2009

Page 1 of 1

Page 22
Image 22
Frymaster BIELA14 Replace filter O-rings, Quarterly FR 3 Q4, Procedure 1Prepare fryer for procedure, 3Replace O-ring