Fujitsu 4Gbit/s FC I/O Modules manual Double-click QueueTarget in Parameters

Models: 4Gbit/s FC I/O Modules

1 40
Download 40 pages 22.57 Kb
Page 28
Image 28
8Double-click "QueueTarget" in "Parameters".

8Double-click "QueueTarget" in "Parameters".

9Set "1" (fixed value) in "New Value", check "Permanent", and click [Change].

10Double-click "LinkSpeed" in "Parameter".

11Set a value in "New Value", check "Permanent", and click [Change].

For the setting values, refer to the ETERNUS Server Connection Guide, etc.

When setting to "1Gb", set "1" to "New Value".

When setting to "2Gb", set "2" to "New Value".

When setting to "4Gb", set "4" to "New Value".

When unnecessary, set "0"(default: Auto-select) to "New Value".

When the setting value for each adapter differs, uncheck "Global".

For the setting values, refer to the ETERNUS Server Connection Guide, etc.

When there are two or more adapters, and the value for each adapter will be changed separately, perform the procedures from Step 4 to 11 for each adapter separately.

12Check the parameters that have been set.

The set values are displayed in "Current" field as a hexadecimal number (when "40" was set, the displayed value is "0x28").

The meanings of the letters displayed at the left of "Parameter" field are as follows:

"G": Global settings are shared by all the adapters

"L": Local settings are specified for each adapter separately

"GL": There are both Global settings and Local settings

When "GL" is displayed, the Local settings are enabled.

66