Fujitsu 4Gbit/s FC I/O Modules manual Connection type Value

Models: 4Gbit/s FC I/O Modules

1 40
Download 40 pages 22.57 Kb
Page 31
Image 31

When selected the adapter to be set and "Driver Parameters" (Individual setting for each adapter)

In the above diagram, "BX620 S3" represents a local server, and "BX600-FC42E - 10:00:00:00:C9:48:FE:0C" represents an installed 4Gbit/s FC I/O Module.

3Click [Topology] in "Adapter Parameter".

4Select a value representing the connection type from the list box to "Value" in "Modify Adapter Parameter", and click [Apply].

Connection type

Value

 

 

FC-AL

0

 

 

Fabric

1

 

 

5Click [QueueDepth] in "Adapter Parameters".

6Set a value in "Value" in "Modify Adapter Parameter", and click [Apply].

The setting value is calculated as follows:

For ETERNUS3000 model 50/GR710/GR720/GR730/GR740/GR820/GR840

For cluster (MSCS/SynfinityCluster): "8"

For other than cluster (MSCS/SynfinityCluster)

When one HBA is connected to one FC-CA (FC port): "16"

When two HBAs are connected to one FC-CA (FC port): "8"

For ETERNUS3000 model 80/100/200/300/400/500/600/700 and ETERNUS4000 model 80/100

Setting value (rounding down decimals) = 40/ (number of 4Gbit/s FC I/O Module connected to one CA port)

When the calculated value is 8 or less, specify "8".

For ETERNUS6000 model 400/500/600/700/800/900/1000/1100 Specify "40".

E

5 4Gbit/s FC I/O Module Details Setting 69

Page 31
Image 31
Fujitsu 4Gbit/s FC I/O Modules manual Connection type Value