Fujitsu 4Gbit/s FC I/O Modules manual Double-click QueueTarget in Adapter Parameters

Models: 4Gbit/s FC I/O Modules

1 40
Download 40 pages 22.57 Kb
Page 32
Image 32
7Double-click "QueueTarget" in "Adapter Parameters".

For ETERNUS4000 model 300/500 and ETERNUS8000

Specify "255".

7Double-click "QueueTarget" in "Adapter Parameters".

8Set "1" (fixed value) in "Value" in "Modify Adapter Parameter", and click [Apply].

9Click "LinkSpeed" in "Adapter Parameters".

10Select the value from the list box to "Value" in "Modify Adapter Parameter", and click [Apply].

For the setting values, refer to the ETERNUS Server Connection Guide, etc.

Setting value "1": Select "1Gb"

Setting value "2": Select "2Gb"

Setting value "4": Select "4Gb"

No setting is necessary: Select "Auto-select" (Default)

When there are two or more adapters, and the setting for each adapter will be changed separately, perform the procedures from Step 2 to 10 for each adapter.

11Check the parameters that have been set.

The set values are displayed in "Value".

If the parameter is displayed in red, the setting is not applied. Click [Apply].

When Topology: 0, QueueDepth: 8, QueueTarget: 1 for all the adapters

12When the settings for all the adapter finishes, select "Exit" from "File" menu, and exit HBAnyware Utility.

After exiting HBAnyware Utility, perform "5.2 Registry Setting" (￿pg.71).

70