Parameter

Status

 

Meaning

flow_control

Read only

0 : None (Not doing flow_control)

 

 

1

: LocSend (Can transmit pause

 

 

 

frame only)

 

 

2

: Rem (Can receive pause frame

 

 

 

only)

 

 

3

: Sym (Can receive and transmit

 

 

 

pause frame)

cardtype

Read only

0 : SX(PW008GE4)

 

 

1

: T(PRIMEPOWER250/450

 

 

secondary LAN port,

 

 

PW008GE5/PW008QG1)

instance

Read and write

Instance Number

adv_10fdx_cap

Read and write

Setting of 10Mbps/FullDuplex

 

 

0

: Invalid

 

 

1

: Valid (Default)

adv_10hdx_cap

Read and write

Setting of 10Mbp/HalfDuplex

 

 

0

: Invalid

 

 

1

: Valid (Default)

adv_100fdx_cap

Read and write

Setting of 100Mbps/FullDuplex

 

 

0

: Invalid

 

 

1

: Valid (Default)

adv_100hdx_cap

Read and write

Setting of 100Mbps/HalfDuplex

 

 

0

: Invalid

 

 

1

: Valid (Default)

adv_1000fdx_cap

Read and write

Setting of 1000Mbps/FullDuplex

 

 

0

: Invalid

 

 

1

: Valid (Default)

adv_1000hdx_cap

Read and write

Setting of 1000Mbps/HalfDuplex

 

 

0

: Invalid

 

 

1

: Valid (Default)

adv_pauseTX

Read and write

Setting of transmit pause frame

 

 

0

: Invalid

 

 

1

: Valid (Default)

adv_pauseRX

Read and write

Setting of receive pause frame

 

 

0

: Invalid

 

 

1

: Valid (Default)

adv_autoneg_cap

Read and write

Setting of AutoNegotiation

 

 

0

: Invalid (Fixed mode)

 

 

1

: Valid (Default)

adv_role_cap

Read and write

Setting of Role (Only 1000Mbps)

 

 

0

: Slave

 

 

1

: Master

 

 

2

: Auto (Default)

lp_10fdx_cap

Read only

Setting of link-partner

 

 

10Mbps/FullDuplex, when link up

 

 

with AutoNegotiation.

 

 

0

: Invalid

 

 

1

: Valid

20